Technical Info and Downloads

    StudioBricks

    Size

    • Many size options are available; can accommodate anything from a solo musician to a large group/band or choir
    • Typical internal ceiling height is 2040mm

    Performance

    • Typical sound insulation performance:
    • Typical sound insulation performance: 46dB in accordance with ISO 717-1
    • Third octave band sound transmission losses available on request, tested in accordance with ISO 140/4

    Flexibility

    • Modular panel design provides a large selection of different size cabins
    • Easy re-location or size adjustment of existing rooms

    Construction

    • Modular, interlocking sound-isolating panels are secured with sound-isolating battens
    • Acoustically sealed base channel controls wall panel placement.
    • Painted panel finish.  Painted white as standard (other colours and designs are available on request)
    • Typical panel weight would be nominally 32kgs/m2
    • Full length acoustically engineered glass door with acoustic seals.

    Ventilation

    • Integral fan unit supplied as standard
    • Acoustically isolated HVAC connections are also available

    Electrical components

    • Client’s own electrical cables can be fed into the cabin via a cable port
    • Surface fixed lighting is available if required
    • Additional safety items such as fire alarm detectors, sounders and strobe lights can be installed within the rooms (additional works by incumbent suppliers may be required)

    Installation requirements

    • Minimum clearance over room height is 200mm
    • Minimum spacing of 50mm from walls and 250mm from adjacent cabins
    • Supporting floor structures will accommodate the room loadings, be flat, level and true
    • Floor level tolerance provides a minimum flat and level surface of 3mm over 1000mm
    • Ventilation of the room where the cabin is located is required
    • The cabin is designed for self-build
    • Installation service (if required) demands room to be cleared of furniture prior to the arrival of our installation team
    • Site inspection can be carried out by our Acoustic Engineer and acoustically trained staff, before delivery/installation schedule is agreed

    Options and additions

    • Closure panels between and around cabins
    • Glazed acoustically engineered windows available for control room purposes, observation, security or to provide natural light
    • Rooms come with cable ports as standard.  Additional sockets, data points etc are available within three-compartment dado trunking, should this be required
    • Rooms come with sound isolating floating floors as standard
    • Sound limiting devices available for fitting in accordance with BB93 and/or Health and Safety requirements
    • Locking door with internal lock override available on request
    • Surface fixed lighting available
    • Additional safety items such as fire alarm detectors, sounders and strobe lights can be installed within the rooms (additional works by incumbent suppliers may be required)