View the STUDIOBRICKS introduction video – click here!

 

STUDIOBRICKS

Size

  • Many size options are available; can accommodate anything from a solo musician to a large group/band or choir
  • Typical internal ceiling height is 2040mm

Performance

  • Typical sound insulation performance:
  • Typical sound insulation performance: 46dB in accordance with ISO 717-1
  • Third octave band sound transmission losses available on request, tested in accordance with ISO 140/4

Flexibility

  • Modular panel design provides a large selection of different size cabins
  • Easy re-location or size adjustment of existing rooms

Construction

  • Modular, interlocking sound-isolating panels are secured with sound-isolating battens
  • Acoustically sealed base channel controls wall panel placement. 
  • Painted panel finish.  Painted white as standard (other colours and designs are available on request)
  • Typical panel weight would be nominally 32kgs/m2
  • Full length acoustically engineered glass door with acoustic seals. 

Ventilation

  • Integral fan unit supplied as standard
  • Acoustically isolated HVAC connections are also available

Electrical components

  • Client’s own electrical cables can be fed into the cabin via a cable port
  • Surface fixed lighting is available if required
  • Additional safety items such as fire alarm detectors, sounders and strobe lights can be installed within the rooms (additional works by incumbent suppliers may be required)

Installation requirements

  • Minimum clearance over room height is 200mm
  • Minimum spacing of 50mm from walls and 250mm from adjacent cabins
  • Supporting floor structures will accommodate the room loadings, be flat, level and true
  • Floor level tolerance provides a minimum flat and level surface of 3mm over 1000mm
  • Ventilation of the room where the cabin is located is required
  • The cabin is designed for self-build
  • Installation service (if required) demands room to be cleared of furniture prior to the arrival of our installation team
  • Site inspection can be carried out by our Acoustic Engineer and acoustically trained staff, before delivery/installation schedule is agreed

Options and additions

  • Closure panels between and around cabins
  • Glazed acoustically engineered windows available for control room purposes, observation, security or to provide natural light
  • Rooms come with cable ports as standard.  Additional sockets, data points etc are available within three-compartment dado trunking, should this be required
  • Rooms come with sound isolating floating floors as standard
  • Sound limiting devices available for fitting in accordance with BB93 and/or Health and Safety requirements
  • Locking door with internal lock override available on request
  • Surface fixed lighting available
  • Additional safety items such as fire alarm detectors, sounders and strobe lights can be installed within the rooms (additional works by incumbent suppliers may be required)